Fixed Gas Detector (Diffusion Type) KD-14
-
-
- Model
- KD-14
- Gas Detected
- Combustible gas and toxic gas
- Detection Principle
- Hot wire semiconductor and Catalytic combustion
- Detection Range
- 0-2000ppm, 0-100%LEL
- Dimensions
- W158 x H158 x D68mm
Extractive type gas detector. Easy to replace its sensor unit.
Features
- Compact designed diffusion type gas detector
- Easy to replace unit type sensor
- Water and dust-proof construction (Degree of protection: IP65)
- Explosion-proof type (Ex d IIC T5)
Specifications
Model | KD-14A | KD-14B |
Sampling Method | Diffusion | |
Detection Principle | Hot wire semiconductor | Catalytic combustion |
Gas Detected | Hydrogen | |
Detection Range | 0 to 2000 ppm | 0 to 100 %LEL |
Explosion-proof | Ex d IIB + H2T4 | |
Degree of Protection | IP65 | |
Applicable Cable | Cable diameter: 10mm to 13mm 4-core shield cable: CVV-S 0.75mm2, 1.25mm2 or 2.0mm2 |
|
Operating Temperature/Humidity | -10 to +50 °C 10% to 90 %RH (0 to 50 °C) |
|
Power Supply | Supplied by indicator unit | |
Dimensions | W158 x H158 x D68 mm | |
Weight | Approx. 1.2kg |
Connectable Alarm Units
Approvals
Type Approved by TIIS Explosion-proof certification
IP65 rating